Rating from 800VA to 3KVA, Otima provides server-grade full power protection from power failure, spikes and surge in small footprint with enhanced output power factor 0.9. Combining flexible rack/tower form factor and easy-shift LCD panel design, this series is perfect for networking, telecom, server and mission-critical applications.
Overview
Main Features
- Pure sine wave
- User-friendly and easy-shift LCD display
- High flexibility with Rack/Tower design
- Output power factor 0.9
- Programmable power management outlets
- ECO (Efficiency Corrective Optimizer) operation for energy saving
- Boost and Buck AVR for voltage stabilization
- Hot-swappable battery design
- Multiple communications available
- Optional HID Power Device USB Port
Specifications
MODEL | Otima II 800 | Otima II 1.1K(L) | Otima II 1.5K | Otima II 2K(L) | Otima II 2.5K | Otima II 3K(L) | |
CAPACITY | 800 VA / 720 W | 1100 VA / 990 W | 1500 VA / 1350 W | 2000 VA / 1800 W | 2500 VA / 2250 W | 3000 VA / 2700 W | |
INPUT | |||||||
Nominal Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC | ||||||
Acceptable Voltage Range | 81-152 VAC or 162-290 VAC | ||||||
Frequency Range | 60/50 Hz (auto sensing) | ||||||
OUTPUT | |||||||
Output Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC | ||||||
Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 1 Hz | ||||||
Transfer Time | Typical 2-6 ms, 10ms max. | ||||||
Waveform (Batt. Mode) | Pure Sine Wave | ||||||
Voltage Regulation (Batt. Mode) | ± 1.5% (before battery alarm) | ||||||
Current Crest Ratio | 3:1 | ||||||
Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) | ||||||
EFFICIENCY | |||||||
Battery Mode | up to 90% | up to 91% | up to 92% | ||||
Buck & Boost Mode | 95% | ||||||
ECO Mode | 97% | ||||||
BATTERY | |||||||
Long-run Model | Charging Current (max.) | N/A | 1A/2A/4A/6A/8A | N/A | 1A/2A/4A/6A/8A | N/A | 1A/2A/4A/6A/8A |
Long-run Model | Charging Voltage | N/A | 27.4 VDC ± 1% | N/A | 54.8 VDC ± 1% | N/A | 82.1 VDC ± 1% |
Standard Model | Battery Type & Numbers | 12 V/7 Ah x 2 | 12 V/9 Ah x 2 | 12 V/7 Ah x 4 | 12 V/9 Ah x 4 | 12 V/7 Ah x 6 | 12 V/9 Ah x 6 |
Standard Model | Charging Current (max.) | 1.5 A | |||||
Standard Model | Charging Voltage | 27.4 VDC ± 1% | 54.8 VDC ± 1% | 82.1 VDC ± 1% | |||
Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | |||||
PROTECTION | |||||||
Full Protection | Overload, discharge, and overcharge protection | ||||||
INDICATORS | |||||||
LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | ||||||
ALARM | |||||||
Battery Mode | Sounding every 10 seconds | ||||||
Low Battery | Sounding every 2 seconds | ||||||
Overload | Sounding every second | ||||||
Fault | Continuously sounding | ||||||
ENVIRONMENT | |||||||
Operating Humidity | 0~90% RH @ 0- 40°C (non-condensing) | ||||||
Noise Level | Less than 45dB | ||||||
PHYSICAL | |||||||
Standard Model | Dimension, DXWXH (mm) | 410 x 438 x 88 | 510 x 438 x 88 | 630 x 438 x 88 | |||
Standard Model | Net Weight (kgs) | 12.9 | 13.4 | 19.5 | 21.5 | 27.7 | 29.3 |
Long-run Model | Dimension, DXWXH (mm) | N/A | 410 x 438 x 88 | N/A | 410 x 438 x 88 | N/A | 110/115/120/127 VAC: 510 x 438 x 88; 208/220/230/240 VAC: 410 x 438 x 88 |
Long-run Model | Net Weight (kgs) | N/A | 9 | N/A | 10.8 | N/A | 110/115/120/127 VAC: 13.9; 208/220/230/240 VAC: 11.9 |
MANAGEMENT | |||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |