Galleon III offers a better output power factor up to 1.0, providing higher performance and efficiency for a variety of precision equipment. In comparison with our previous model of Galleon One, Galleon III has increased 3% efficiency with better performance. It is also more compact with size reduction, which saves space.
Overview
Main Features
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction 0.99
- Output power factor 1.0
- 50/60 Hz Frequency Converter Mode
- Wide input voltage (110 V – 300 V)
- ECO mode for energy saving
- Smart battery charger design to optimize battery performance
- Comprehensive display allows easy monitoring and access of UPS status
- SNMP/USB/RS-232 multiple communications
- Generator compatible
Specifications
| MODEL | Galleon III 1K-2B | Galleon III 1K-3B | Galleon III 1.5K | Galleon III 2K-4B | Galleon III 2K-6B | Galleon III 3K | |
| CAPACITY | 1000 VA / 1000 W | 1500 VA / 1500 W | 2000 VA / 2000 W | 3000 VA / 3000 W | |||
| PHASE | Single phase with ground | ||||||
| INPUT | |||||||
| Voltage Range | 110 ~ 300 VAC (Based on load at 50%) ; 160 ~ 300 VAC (Based on load at 100%) | ||||||
| Nominal Voltage | 200*/208*/220/230/240 VAC | ||||||
| Frequency Range | 40 Hz~70 Hz | ||||||
| Power Factor | ≧ 0.99 @ Nominal Voltage (100% load) | ||||||
| Harmonic Distortion (THDi) | ≦ 5% @ nominal voltage (100% load) | ||||||
| OUTPUT | |||||||
| Output Voltage | 200*/208*/220/230/240 VAC | ||||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||||
| Transfer Time | AC Mode to Battery Mode | Zero | |||||
| Transfer Time | ECO to Battery mode | 8 ms (Typical), 10 ms(max) | |||||
| Transfer Time | Inverter to Bypass | 4 ms (Typical) | |||||
| Waveform (Batt. Mode) | Pure Sine Wave | ||||||
| Current Crest Ratio | 3:1 | ||||||
| Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ||||||
| Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz | ||||||
| EFFICIENCY | |||||||
| Battery Mode | 96% | 97% | |||||
| ECO Mode | 92% | 93% | 94% | ||||
| AC Mode | 86% | 89% | 88% | 89% | 91% | ||
| BATTERY | |||||||
| Standard Model | Battery Type | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | |
| Standard Model | Charging Current (max.) | 1.5 A | |||||
| Standard Model | Charging Voltage | 27.4VDC ± 1% | 41.0 VDC ± 1% | 54.8VDC ± 1% | 82.2 VDC ± 1% | ||
| Standard Model | Numbers | 2 | 3 | 4 | 6 | ||
| Standard Model | Typical Recharge Time | 4 hours recover to 90% capacity | |||||
| INDICATORS | |||||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||||
| ENVIRONMENT | |||||||
| Operating Humidity | 20~95% RH @ 0- 50°C (non-condensing) | ||||||
| Noise Level | Less than 50dB @ 1 Meter | ||||||
| PHYSICAL | |||||||
| Standard Model | Dimension, D X W X H (mm) | 282 X 145 X 220 | 397 X 145 X 220 | 421 X 190 X 318 | |||
| Standard Model | Net Weight (kgs) | 9.8 | 11.4 | 13.8 | 17 | 22.5 | 26.2 |
| MANAGEMENT | |||||||
| Optional external Slot (for SNMP, Dry contact, …) | Power management from SNMP manager and web browser | ||||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | ||||||
| STANDARD | |||||||
| EMC/Safety | CE (EMC: EN62040-2 C2) | ||||||
Downloads