Galleon III 6KVA/10KVA employs digital control technology, featuring fast self-diagnosis and fault-handling capabilities. Its highly integrated circuits and optimized design enhance anti-interference capabilities, ensuring stable performance. With a full-load efficiency of up to 95%, it significantly reduces energy consumption and operating costs. The input power factor exceeds 0.99, and current harmonics are below 4%, effectively preventing additional energy loss and eliminating grid pollution. Its ultra-wide voltage input range adapts to various operating conditions, easily handling harsh power environments and reducing the frequency of switching to battery power. Additionally, it supports generator input with an isolation design, providing a clean, safe, and stable power supply for loads.
Overview
Main Features
- True double-conversion
- DSP technology guarantees high performance
- Output power factor 1
- Wide input voltage range (110-300 VAC)
- High efficiency up to 95%
- Active input power factor correction 0.99
- 50Hz/60Hz frequency converter mode
- Adjustable AC charger up to 6A
- Generator compatible
- High overload capabiliy
- Adjustable battery numbers
- Built-in OVCD protection
Specifications
MODEL | Galleon III 6K(L*) | Galleon III 10K(L*) | |
CAPACITY | 6000 VA / 6000 W | 10000 VA / 10000 W | |
PHASE | 1 phase in / 1 phase out | ||
INPUT | |||
Voltage Range | 110~300VAC ± 3 % at 60% load 176~300VAC ± 3 % at 100% load | ||
Nominal Voltage | 208/220/230/240 VAC | ||
Frequency Range | 46~54 Hz or 56~64 Hz 40 ~ 70 Hz (In generator mode) | ||
Power Factor | ≧ 0.99 @ full load | ||
THDi | <4% @100% Load | ||
OUTPUT | |||
Output Voltage | 208*/220/230/240 VAC | ||
AC Voltage Regulation (Batt. Mode) | ± 1% | ||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||
Transfer Time | AC Mode to Batt. Mode | Zero | |
Transfer Time | Inverter to Bypass | zero | |
Waveform (Batt. Mode) | Pure Sinewave | ||
Current Crest Ratio | 3:1 (max.) | ||
Harmonic Distortion | ≦1 % THD (Linear Load), ≦ 4 % THD (Non-linear Load) | ||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||
Overload | AC Mode | 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% transfer to bypass | |
Overload | Battery Mode | 100-110% for 3 min, 110-130% for 30s ,>130% immediately | |
EFFICIENCY | |||
Battery Mode | 0.92 | ||
AC Mode | 0.95 | ||
BATTERY | |||
Long-run Model | Battery Type | Depending on applications | |
Long-run Model | Charging Current (max.) | 2A (Default) ,1A/2A/4A/6A/8A adjustable | |
Long-run Model | Charging Voltage | (13.65VDC x battery number) ± 1% | |
Long-run Model | Numbers | 16-20** | |
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH |
Standard Model | Charging Current (max.) | 1.0 A | |
Standard Model | Charging Voltage | 218.4 VDC ± 1% | 273 VDC ± 1% |
Standard Model | Numbers | 16 | 20 |
Standard Model | Typical Recharge Time | 7 hours recover to 90% capacity | 9 hours recover to 90% capacity |
ENVIRONMENT | |||
Noise Level | Less than 55dBA @ 1 Meter | Less than 58dB @ 1 Meter | |
Operation Humidity | > 95% RH @ 0- 40°C (non-condensing) | ||
PHYSICAL | |||
Standard Model | Dimension, D X W X H (mm) | 369 x 190 x 688 | 442 x 190 x 688 |
Standard Model | Net Weight (kgs) | 55 | 74 |
Long-run Model | Dimension, D X W X H (mm) | 369 x 190 x 318 | |
Long-run Model | Net Weight (kgs) | 14 | 15 |
MANAGEMENT | |||
Optional SNMP | Power management from SNMP manager and web browser | ||
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC |
Downloads