InfiniSolar VII TWIN is the upgraded version of our InfiniSolar V first generation. This second-generation inverter can accept a high PV voltage range and this feature will facilitate PV system installation. Besides, the battery independence feature will keep the inverter running whether the battery is connected or not. We also offer parallel operation functions up to 9 units for 6KW. It provides high flexibility for future power expansion.
Overview
Main Features
- Maximum PV input current 27A
- Dual outputs for smart load management
- Programmable supply priority for PV, Battery or Grid
- User-adjustable charging current and voltage
- Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
- Monitoring software for real-time status display and control
- Parallel operation up to 9 units
Specifications
MODEL | InfiniSolar V II TWIN 6KW | |
Maximum PV Input Power | 7000W | |
Rated Output Power | 6000W | |
Maximum Charging Power | 6000W | |
GRID-TIE OPERATION | ||
PV INPUT (DC) | ||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 130VDC / 150 VDC | |
MPP Voltage Range | 120 VDC ~ 430 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27 A | |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Output Voltage Range | 184-264.5 VAC or 195.5-253 VAC (Selectable) | |
Nominal Output Current | 26A | |
Power Factor | > 0.99 | |
EFFICIENCY | ||
Maximum Conversion Efficiency (DC/AC) | 95% | |
OFF-GRID OPERATION | ||
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |
Maximum AC Input Current | 40 A | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
PV INPUT (DC) | ||
Maximum DC Voltage | 500 VDC | |
MPP Voltage Range | 120 VDC ~ 430 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27 A | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Output Waveform | Pure sine wave | |
Efficiency (DC to AC) | 93% | |
HYBRID OPERATION | ||
PV INPUT (DC) | ||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 130VDC / 150 VDC | |
MPP Voltage Range | 120 VDC ~ 430 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27 A | |
GRID OUTPUT (AC) | ||
Nominal Output Current | 26A | |
Nominal Output Voltage | 220/230/240 VAC | |
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable) | |
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |
Maximum AC Input Current | 40 A | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Efficiency (DC to AC) | 93% | |
Output Waveform | Pure sine wave | |
BATTERY & CHARGER | ||
Nominal DC Voltage | 48 VDC | |
Maximum Charging Current | 120A | |
Maximum Solar Charging Current | 120A | |
Maximum AC Charging Current | 120A | |
GENERAL | ||
PHYSICAL | ||
Dimension, D X W X H (mm) | 120 x 295 x 468 | |
Net Weight (kgs) | 12 | |
INTERFACE | ||
Communication Port | USB or RS-232/Dry Contact | |
Parallel Function | Yes, 9 units | |
ENVIRONMENT | ||
Operating Humidity | 0 ~ 90% RH (No condensing) | |
Operating Temperature | -10°C to 50°C |
Downloads