Axpert King II TWIN is designed with zero transfer time which is perfect for critical devices such as servers and ATMs. It’s equipped with a powerful 120A solar charger and 120A AC charger. The detachable LCD control module allows users to monitor this inverter remotely. It can also expand power capacity to 54KW/55.8KW with 9 units in parallel operation. Axpert King II TWIN is occupied with two outputs. The second output can be scheduled on/off, setting cut-off voltage or SOC and discharging time via LCD setting.
Overview
Main Features
- Dual outputs, for smart load management
- Maximum PV input current increases to 27A
- Zero (0ms) transfer time to protect mission-critical loads such as servers and ATMs
- High PV input voltage range
- Detachable LCD control module with multiple communications
- Selectable high power charging current
- Built-in Wi-Fi for mobile monitoring (App is available)
- Configurable AC/Solar input priority via LCD setting
- Reserved communication port for BMS (RS485 or CAN-BUS)
- USB On-the-Go function
- Parallel operation up to 9 units
Specifications
MODEL | Axpert KING II TWIN 6K | Axpert KING II TWIN 6.2K | |
Rated Power | 6000VA/6000W | 6200VA/6200W | |
Parallel Capability | Up to 9 units | ||
INPUT | |||
Voltage | 230 VAC | ||
Voltage Range | 110-280 VAC | ||
Frequency Range | 50 Hz/60 Hz (Auto sensing) ± 4Hz | ||
Power Factor | ≧ 0.98 @ Nominal Voltage (100% Load) | ||
THDi | ≦ 10% | ||
OUTPUT | |||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | ||
Waveform | Pure sine wave | ||
Harmonic Distortion | ≦3 % THD (Linear Load); ≦ 5 % THD (Non-linear Load) | ||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||
AC Voltage Regulation (Line&Batt. Mode) | 230VAC ± 5% | ||
Transfer Time (AC Mode to Batt. Mode) | 0ms | ||
Transfer Time (Inverter to Bypass) | 4 ms (Typical) | ||
EFFICIENCY | |||
Battery Mode | 92% | ||
ECO Mode | 98% | ||
Line Mode | 94% | ||
BATTERY | |||
Battery Voltage | 40~66 VDC | ||
Floating Charge Voltage | 54 VDC | ||
Overcharge Protection | 66 VDC | ||
PHYSICAL | |||
Dimension, D X W X H (mm) | 140 x 295 x 468 | ||
Net Weight (kgs) | 12 | ||
Communication Port | USB/RS232/RS485/WI-FI/Dry-contact | ||
OPERATING ENVIRONMENT | |||
Operating Humidity | 5% to 95% Relative Humidity(Non-condensing) | ||
Operating Temperature | -10°C to 50°C | ||
Storage Temperature | -15°C to 60°C | ||
SOLAR INPUT | |||
Solar Charger type | MPPT | ||
Maximum PV Array Power | 6000 W | ||
MPPT Range @ Operating Voltage | 120 ~ 430 VDC | ||
Maximum PV Array Open Circuit Voltage | 500 VDC | ||
Maxmum Solar Charge Current | 120A | ||
Maximum AC Charge Current | 120A |